    ## 2021 02 03 
    
    NEXT REV: you've mounted the hotend static, and the motor floating post-loadcell. However, loadcell deflection is really minimal, and you could fix the motor / mount the hotend on loadcells. This would let you touch-probe the bed w/ the nozzle itself, for zero calibration etc. 
    
    
    Jake Read's avatar
    Jake Read committed
    ## 2021 01 24
    
    This part works, new toolchanger feels good also. 
    
    ![he](2021-01-24_hotend.mp4)
    
    ![squeeze](2021-01-24_hotend-squeeze.mp4)
    
    ![print](2021-01-24_hotend-print.mp4)
    
    ## 2020 12 27
    
    Revisioning this to bring it up to speed with toolchanger deltas, also found a new loadcell to suit the smaller toolchanger design, that's UXCell PN `a15110200ux0247`. 
    
    So I've to revision to tighten this up, but it should be pretty straightforward. I think I do this, then fab it all, and can bring loadcell probes in to the mix once I have two of these swapping pretty well... would love to have i.e. an 0.8mm infill tool and 0.4mm perimeter tool. 
    
    - adjustment for smaller loadcell, 
    - adjustment to hotend pinching clamshell
    - rm interference between hotend / bowden top and loadcell 
    - more-better planar constraint on hotend / coolside / front-of-hotend clamshell 
    
    Great, this is done, so I'll fab and then bring heaters & loadcells online. 
    
    ![gg](2020-12-27_glue-gun.png)
    
    
    Jake Read's avatar
    Jake Read committed
    ## 2020 12 10 
    
    Assembled one of these, have some hardware bugs but will continue to bring this online instead of revisioning:
    
    - could use a third thru-bolt to get the planar constraint w/ the second half of the hotend-pinching clamshell 
    - loadcell to bowden connector does not clear (visible in CAD: move out or move up) 
    - m4 head-thru on top of loadcell on hotend not wide enough 
    - more pusher-part (extruder / top half) clearance to plate, notice misalignment / out of squareness at loadcell mount 
    
    
    
    Jake Read's avatar
    Jake Read committed
    ## 2020 12 06
    
    Did a bunch of development for this thing offline. 
    
    ![gg](2020-12-06_gluegun.png)
    
    It's E3D hotend compatible, I'm using a Dragon hotend. Has a loadcell inline to measure extrusion force, hotend fan but no part cooling fan yet, etc.